Users Also Read
Read MCQ's/Objective questions
MCQ's Search Engine
D.C.Basic
A.C.Basic
D.C.Machine
A.C.Machine
A.C. Fundamentals
Alternators
Basic Electricity
Control Systems
D.C. Generators
D.C. Motors
Economics of Power Generation
Electric Heating
Electric Traction
Electric Welding
Electrical Engineering Materials
Electrical Installation and Wiring
Electrical Machine Design
Electrostatics
Electrolysis and Storage of Batteries
Electromagnetic Induction
Illumination
Industrial Drives
Magnetic Circuit & Electromagnetism
Measurement and Instrumentation
Network Theorems And Circuit Theory
Polyphase Induction Motors
Resistance and Ohm's law
Rectifiers and Converters
Refrigeration and Air conditioning
Single Phase Induction Motors
Synchronous Motors
Transformers
Transmission & Dist. of Elect. Power
Home⇒ Engineering⇒
Switchgear and protection
1-Dont try to cram or spend more time here just read it fast and cover syllabus then practice MCQ's cheptor of same topic to check your progress. . |
2-Wrong options are also given but dont concentrate there, Right answer is in bold format. |
Q1 ⇒ Relays can be designed to respond to
changes in all above [other wrong options] [Discuss in forum] resistance, reactance or impedance voltage and current light intensity temperature |
Q2 ⇒ The current zero interruption, in oil
and air blast circuit breakers, is achieved
by both (a) and (b) [other wrong options] [Discuss in forum] lengthening of the gap cooling and blast effect deionizing the oil with forced air none of the above |
Q3 ⇒ Protective relays are devices that detect
abnormal conditions in electrical circuits
by measuring constantly the electrical quantities which differ during normal and abnormal conditions [other wrong options] [Discuss in forum] current during abnormal pondition voltage during abnormal condition none of the above |
Q4 ⇒ Insulation resistance of high voltage
circuit breakers is more than 100 mega ohms [other wrong options] [Discuss in forum] 1 mega ohms 10 mega ohms 500 mega ohms |
Q5 ⇒ Wave trap is used to trap waves of higher frequencies entering generator or transformer units [other wrong options] [Discuss in forum] power frequencies either of the above none of the above |
Q6 ⇒ Induction cup relay is operated due to
changes in all of the above [other wrong options] [Discuss in forum] current voltage impedance |
Q7 ⇒ For which of the following protection
from negative sequence currents is
provided ? Generators [other wrong options] [Discuss in forum] Motors Transmission line Transformers |
Q8 ⇒ Which of the following parameter can
be neglected for a short line ? Capacitance [other wrong options] [Discuss in forum] Inductance Resistance Reactance |
Q9 ⇒ Overfluxing protection is recommended
for generator transformer of the power plant [other wrong options] [Discuss in forum] distribution transformer auto-transformer of the power plant station transformer of the power plant |
Q10 ⇒ A fuse is connected in series with circuit [other wrong options] [Discuss in forum] in parallel with circuit either in series or in parallel with circuit none of the above |
Q11 ⇒ To limit short-circuit current in a power
system ____ are used. reactors [other wrong options] [Discuss in forum] earth wires isolators H.R.C. fuses |
Q12 ⇒ Which of the following relays is used for
protection of motors against overload ? Thermal relay [other wrong options] [Discuss in forum] Buchholz relay Impedance relay Electromagnetic attraction type None of the above |
Q13 ⇒ The rating of a circuit breaker is
generally determined on the basis of symmetrical fault current [other wrong options] [Discuss in forum] line-to-line fault current single line to ground fault current double line to ground fault current |
Q14 ⇒ Merz-Price protection is used for alternators [other wrong options] [Discuss in forum] short transmission lines long transmission lines air cooled transformers |
Q15 ⇒ The material used for bus-bars should
have all of the above [other wrong options] [Discuss in forum] low cost higher softening temperature low resistivity |
Q16 ⇒ Outdoor switchgear is generally used
for voltage beyond 66 kV [other wrong options] [Discuss in forum] 11 kV 33 kV 132 kV |
Q17 ⇒ SF6 gas is nontoxic [other wrong options] [Discuss in forum] is yellow in colour is lighter than air has pungent small none of the above |
Q18 ⇒ Overload relays are of ____ type. all above [other wrong options] [Discuss in forum] induction solid state thermal electromagnetic |
Q19 ⇒ Air blast circuit breaker is used for repeated duty [other wrong options] [Discuss in forum] over currents short duty intermittant duty |
Q20 ⇒ The voltage appearing across the contacts
after opening of the circuit breaker
is called ____ voltage. recovery [other wrong options] [Discuss in forum] surge operating arc none of the above |
Or |