Users Also Read
Read MCQ's/Objective questions
MCQ's Search Engine
Airport Engineering
Applied Mechanics & Graphic Statics
Building Materials and Construction
Concrete Technology (R.C.C.)
Construction Planning & Manag., PERT
Dock and Harbor Engineering
Estimation Costing, Quantity Surveying
Fluid Mechanics/Hydraulic Engineering
Highways Engineering
Railway Engineering
Sanitary Engineering
Soil Mechanics and Foundation Engg
Steel Structures & it's Design
Strength of Materials
Surveying
Theory/Design of Structures Analysis
Tunnel Engineering
Water Res. Engg, Irrigation, Hydrology
Air Pollution
Home⇒ Engineering⇒
Environmental engineering
1-Dont try to cram or spend more time here just read it fast and cover syllabus then practice MCQ's cheptor of same topic to check your progress. . |
2-Wrong options are also given but dont concentrate there, Right answer is in bold format. |
Q1 ⇒ The layout of distribution system in which water flows towards the outer periphery is radial system [other wrong options] [Discuss in forum] ring system dead end system grid iron system |
Q2 ⇒ The suitable layout of distribution system for a city with roads of rectangular pattern is grid iron system [other wrong options] [Discuss in forum] dead end system ring system radial system |
Q3 ⇒ The commonly used material for water supply pipes, which has the properties of being strong, not easily corroded and long life but is heavy and brittle is cast iron [other wrong options] [Discuss in forum] steel copper reinforced cement concrete |
Q4 ⇒ The method of analysis of distribution system in which the domestic supply is neglected and fire demand is considered is circle method [other wrong options] [Discuss in forum] equivalent pipe method electrical analysis method Hardy cross method |
Q5 ⇒ The type of valve which is provided to control the flow of water in the distribution system at street corners and where the pipe lines intersect is sluice valve [other wrong options] [Discuss in forum] check valve safety valve scour valve |
Q6 ⇒ The type of valve which allows water to flow in one direction but prevents its flow in the reverse direction is reflux valve [other wrong options] [Discuss in forum] sluice valve air relief valve pressure relief valve |
Q7 ⇒ Scour valves are provided at every depression and dead ends to drain out the waste water that may collect there [other wrong options] [Discuss in forum] at street corners to control the flow of water at the foot of rising main along the slope to prevent back running of water at every summit of rising mains |
Q8 ⇒ A sewer that receives the discharge of a number of house sewers is called lateral sewer [other wrong options] [Discuss in forum] house sewer intercepting sewer submain sewer |
Q9 ⇒ A pipe conveying sewage from plumbing system of a single building to common sewer or point of immediate disposal is called house sewer [other wrong options] [Discuss in forum] lateral sewer main sewer submain sewer |
Q10 ⇒ For a country like India, where rainfall is mainly confined to one season, the suitable sewerage system will be separate system [other wrong options] [Discuss in forum] combined system partially combined system partially separate system |
Q11 ⇒ Average rate of water consumption perhead per day as per Indian Standard is 135 litres [other wrong options] [Discuss in forum] 100 litres 165 litres 200 litres |
Q12 ⇒ Sewerage system is usually designed for 25 years [other wrong options] [Discuss in forum] 10 years 50 years 75 years |
Q13 ⇒ Which of the following sewers is preferred for combined system of sewage ? egg shaped sewer [other wrong options] [Discuss in forum] circular sewer rectangular sewer none of the above |
Q14 ⇒ The suitable system of sanitation for area of distributed rainfall throughout the year with less intensity is combined system [other wrong options] [Discuss in forum] separate system partially separate system partially combined system |
Q15 ⇒ The water carriage system of collection of waste product requires treatment before disposal [other wrong options] [Discuss in forum] is cheaper in initial cost than dry conservancy system creates hygenic problem all of the above |
Q16 ⇒ If the time of concentration is 9 minutes, then the intensity of rainfall according to British Ministry of Health formula will be 40 mm/hr [other wrong options] [Discuss in forum] 4 mm/hr lOmm/hr 20 mm/hr |
Q17 ⇒ The time of concentration is defined as sum of (a) and (b) [other wrong options] [Discuss in forum] the time taken by rainfall water to run from most distant point of water shed to the inlet of sewer the time required for flow of water in sewer to the point under consideration difference of (a) and (b) |
Q18 ⇒ The specific gravity of sewage is slightly greater than 1 [other wrong options] [Discuss in forum] much greater than 1 slightly less than 1 equal to 1 |
Q19 ⇒ The waste water from bath rooms, kitchen etc. is called Sullage [other wrong options] [Discuss in forum] Refuse Sewage Garbage |
Q20 ⇒ The self cleansing velocity for all sewers in India is usually 1.0 m/sec to 1.2 m/sec [other wrong options] [Discuss in forum] less than 1.0 m/sec 1.5 m/sec to 2.0 m/sec 3.0 m/sec to 3.5 m/sec |